top of page

Home / Products / Stainless Steel Fittings / Forged Needle Valve Tube x Tube Fractional - SS 316 Instrumentation Valves

Forged Needle Valve Tube x Tube Fractional - SS 316 Instrumentation Valves

SKU ID: FNVT

Description

Forged Needle Valve Tube x Tube Fractional - SS 316 Instrumentation Valves

The FNVT is a forged needle valve tube x tube fractional that isolates or controls flow in the line, with a body built for repeated operation. The 316 stainless steel body resists corrosion in gas, hydraulic and pneumatic service. Dimensionally interchangeable with equivalent Parker, Swagelok fittings.

Sizes and Part Numbers

Sr. No.

Size

Ref Part No.

1

1/8 Inch

FNVT-2

2

1/4 Inch

FNVT-4

3

3/8 Inch

FNVT-6

4

1/2 Inch

FNVT-8

5

3/4 Inch

FNVT-12

6

1 Inch

FNVT-16


Technical Specifications

Size

1/8 Inch to 1 Inch

End Connection

NPT, BSPT, Socket Weld, Butt Weld, Tube Fitting

Pattern

Straight

Working Pressure

6000 Psi (413 Bar)

Temperature Rating

PTFE 450°F (232°C) · Grafoil 700°F (371°C)

Material of Construction

SS 316, SS 304, CS, F11

Stem Packing

PTFE, Grafoil

Orifice

Dia 4.7

Panel Mounting

On request

Sour Gas Service

Optional, conforming to NACE Std. MR-01-75


Features

  • Integral bonnet design

  • Bonnet: back seated, blow-out proof

  • Packing nut design permits packing adjustment in the open or closed position

  • Spindle: ground and thread rolled

  • Spindle tip: non-rotating, shut-off type stellited, regulating stellited and soft seated

  • Bonnet pusher: silver plated for anti-galling, for increased stem cycle life

  • Leak-tight seal with low operating torque

  • Heat code traceability

  • All valves 100% factory tested prior to shipment


Materials of Construction

Sr. No.

Description

Qty.

Material

1

Body

1

SS 316

2

Bonnet Pusher

1

SS 316

3

Stem

1

SS 316

4

Gland

1

SS 316

5

Body Nut

1

SS 316

6

Gland Nut

1

SS 316

7

Gasket

1

PTFE

8

Packing

1

PTFE

9

Dust Cap

1

LDPE

10

Grub Screw

1

CS

11

Handle

1

SS 304


Testing

  • Pneumatic seat test at 1/4 of working pressure

  • Hydrostatic shell test at 1.5 times working pressure

  • Optional tests available on request


Lubrication

Dye molly sulphide.


Application

For fractional OD tube systems, the forged body and tube x tube ends give a compact isolation and regulating point on instrument impulse and sampling lines.